CORTEXA
← Browse
arxiveess.SPeess.SYphysics.med-phphysics.optics2026-07-05

Light Coils: MRI with Fully Optical Data and Power Transmission

Zining Liu, Morteza Teymoori, Jakob Gerlach, Reza Aghabagheri, Henning Helmers, Michael Bock, Caglar Ataman, Ali Oezen

In MRI, dense receiver coil arrays with a high number of coil elements are used to efficiently detect and encode the signal. Further increasing the number of coils is hampered by electrical cabling and massive electronics that introduce electromagnetic coupling, integration complexity and even safety constraints. Here we introduce the novel Light Coils concept, a fully optical MRI receive architecture in which data transmission, front-end power delivery, and coil detuning are all implemented optically, thereby reducing the massive galvanic cabling to a few optical fibers. For signal encoding, Mach-Zehnder modulators (MZM) are used to convert the MR signal from each coil onto a C-band optical carrier. The preamplifiers are driven via a power-over-fiber (PoF) system that uses a high-efficiency photovoltaic (PV) cell for optical-to-electrical power conversion. A pulse-sequence-triggered optical path controls active detuning. Jointly optimizing modulator bias, optical power and front-end gain under realistic receiver chain conditions, Light Coils can match the signal-to-noise ratio (SNR) of conventional RF coil systems with galvanic cables at MZM input powers of 5-10mW and photonic power converter inputs of 80-100mW. At a clinical 3T MRI system, we show in vivo human brain imaging with a single-channel Light Coil element with an image quality and SNR comparable to a conventional coaxial readout using the identical coil element. Extending the concept to a four-channel array using dense wavelength-division multiplexing over a single fiber, we demonstrate wavelength-selective routing with inter-channel optical isolation exceeding 28dB, reduced noise correlation compared with the galvanic reference, and parallel imaging. These results establish a scalable route towards lightweight, modular, and potentially ultra-dense MRI receive arrays based on integrated photonics and power-over-fiber.

View free PDFSource page

Related papers

arxivphysics.med-pheess.SYphysics.ins-detphysics.optics2026-07-10

Optically-powered Low Power Low Noise Amplifiers for MRI

Reza Aghabagheri, Jakob Gerlach, Zining Liu, Morteza Teymoori, Caglar Ataman, Michael Bock, et al.

Purpose: Fully optical receive coils can potentially allow dense receiver arrays with a large channel count, reduced channel crosstalk, and less cable clutter. The power requirements of conventional low-noise amplifiers (LNAs) are prohibitive for simultaneously driving many coils…

View free PDFSource page
arxiveess.SYphysics.med-phphysics.optics2026-07-07

Optical Detuning Strategies for Shielded Loop Resonators

Jakob Gerlach, Reza Aghabagheri, Zining Liu, Shuai Liu, Morteza Teymoori, Caglar Ataman, et al.

Purpose: To compare detuning performance and evaluate the power requirements of optical detuning methods, and to demonstrate the feasibility of an optically detuned four-channel receive array. Methods: Four optical detuning methods were compared in simulations, bench tests, and p…

View free PDFSource page
arxivphysics.opticseess.SP2026-07-08

Beyond white- and black-box modeling tools in optical communications and optical computing: physics-informed data-driven modeling

Isidora Teofilovic, Sergio Hernandez Fernandez, Metodi P. Yankov, Christophe Peucheret, Darko Zibar, Francesco Da Ros

Efficient optimization and control of photonic computing and communication systems increasingly rely on accurate surrogate models/digital twins. While data-driven models may achieve faster inference than traditional physics-based methods, they typically suffer from poor training…

View free PDFSource page
arxivcs.ETeess.IVeess.SPphysics.med-ph2026-07-23

Quantum Adaptive Sensing for Accelerated MRI

Asmit Ganguly, Suprajit Dewanji, Chenyang Zhao, Danny J. J. Wang

Compressed sensing accelerates MRI by reconstructing images from undersampled k-space, but performance depends strongly on sampling distribution. We propose an adaptive framework that selects Cartesian phase-encode lines sequentially using a fixed-cardinality quadratic unconstrai…

View free PDFSource page
arxiveess.SYeess.IVeess.SP2026-07-13

WULPUS PRO: Multi-mode Ultra-Low-Power Wearable Ultrasound and Array Imaging with CMUT Support

Sergei Vostrikov, Federico Villani, Cedric Hirschi, Jinhao Lu, Jonas Welsch, Martin Angerer, et al.

Wearable ultrasound enables continuous monitoring of physiological processes such as muscle dynamics, bladder volume, and cardiovascular activity. Existing fully wearable ultra-low-power platforms are limited to shallow, low-channel A-mode sensing, while larger multi-mode systems…

View free PDFSource page
arxiveess.SPeess.SY2026-06-30

Rethinking Energy Efficiency in Cell-Free Massive MIMO: The Role of Processing and Optical Fronthaul

Ozan Alp Topal, Özlem Tuğfe Demir, Cicek Cavdar

Cell-free massive MIMO promises uniformly high performance by combining densely distributed radio units, coherent transmission, and centralized processing. Unlike earlier radio generations, it depends on dense fronthaul connectivity and a virtualized cloud-RAN architecture. In th…

View free PDFSource page