CORTEXA
← Browse
arxiveess.SYphysics.med-phphysics.optics2026-07-07

Optical Detuning Strategies for Shielded Loop Resonators

Jakob Gerlach, Reza Aghabagheri, Zining Liu, Shuai Liu, Morteza Teymoori, Caglar Ataman, Michael Bock, Ali Caglar Oezen

Purpose: To compare detuning performance and evaluate the power requirements of optical detuning methods, and to demonstrate the feasibility of an optically detuned four-channel receive array. Methods: Four optical detuning methods were compared in simulations, bench tests, and phantom measurements at 3T against conventional galvanic detuning. Passive detuning was also tested as an additional wireless detuning option. Optical power requirements for the detuning networks were investigated, and a flexible, optically detuned 4-channel shielded-loop resonator (SLR) array was constructed and tested in vivo. Results: A photodiode-PIN diode combination exhibited the highest unloaded Q (68.6) and Q ratio (1.9), with detuning performance and signal-to-noise ratio comparable to that of galvanic detuning at an optical power of 10 mW. Using this detuning strategy, in vivo images of the knee and brain were successfully acquired with a 4-channel flexible array. Conclusion: Optical detuning is a practical alternative to conventional galvanic detuning in flexible SLR arrays. With advances in optical signal and power transmission, optimizing optical detuning while meeting manageable power requirements is an important step toward fully optical receive-coil arrays. This study provides a baseline for the total optical power required for active detuning in such optical coil systems.

View free PDFSource page

Related papers

arxiveess.SPeess.SYphysics.med-phphysics.optics2026-07-05

Light Coils: MRI with Fully Optical Data and Power Transmission

Zining Liu, Morteza Teymoori, Jakob Gerlach, Reza Aghabagheri, Henning Helmers, Michael Bock, et al.

In MRI, dense receiver coil arrays with a high number of coil elements are used to efficiently detect and encode the signal. Further increasing the number of coils is hampered by electrical cabling and massive electronics that introduce electromagnetic coupling, integration compl…

View free PDFSource page
arxivphysics.med-pheess.SYphysics.ins-detphysics.optics2026-07-10

Optically-powered Low Power Low Noise Amplifiers for MRI

Reza Aghabagheri, Jakob Gerlach, Zining Liu, Morteza Teymoori, Caglar Ataman, Michael Bock, et al.

Purpose: Fully optical receive coils can potentially allow dense receiver arrays with a large channel count, reduced channel crosstalk, and less cable clutter. The power requirements of conventional low-noise amplifiers (LNAs) are prohibitive for simultaneously driving many coils…

View free PDFSource page
arxivphysics.opticseess.SY2026-07-17

Machine Learning-Driven Design of Mixed-Pitch Grating Couplers for Co-Packaged Optics Applications

Yu Dian Lim, Yun Da Chua, Wai Cheung Ma, Yeow Kheng Lim, Chuan Seng Tan

A mixed-pitch grating coupler which can couple a wide range of wavelengths is preferred in its application in co-packaged optics (CPO). However, the design and optimization of such grating coupler is complex. In this work, we developed software with integrated deep neural network…

View free PDFSource page
arxivq-bio.QMeess.SY2026-07-09

Model Predictive Controller to Regulate Cortisol Levels in Individuals With Adrenal Insufficiency

Renuka Joshi, Nayana Saha, Vittal Srinivasan, Stanislaw H. Zak, Cary N. Mariash

A model predictive controller (MPC) is used to construct a virtual assistant to aid a physician in prescribing cortisol replacement therapy for patients with adrenal insufficiency (AI). AI, also known as hypocortisolism, is a condition that occurs due to a low concentration of co…

View free PDFSource page
arxivphysics.med-phcs.CV2026-07-01

Closed-loop coupling of personalised and foundation models for real-time treatment guidance with MRI

James Grover, Emily A. Hewson, Andrew Phair, Michael Ferraro, Hilary L. Byrne, Paul Keall, et al.

Image-guided therapies, including radiotherapy, biopsy and deep brain stimulation, rely on real-time targeting of anatomical structures. However, in the presence of motion, imaging latencies create a temporal misalignment between observed and true anatomy, compromising treatment…

View free PDFSource page
arxiveess.SY2026-07-19

Multi-scale closed-loop melt pool control for LPBF via policy optimization

Junan Lin, Riccardo Zuliani, Baris Kavas, Markus Bambach, John Lygeros, Efe C. Balta

Laser powder bed fusion (LPBF) is a metal additive manufacturing process where temperature stabilization is of vital importance to avoid defects such as distortion and cracking. Existing control methods require manual tuning, increasing the risk of part failure when printing comp…

View free PDFSource page