CORTEXA
← Browse
arxivcs.CVeess.IV2026-07-12

Quantum Compressed Sensing CT Reconstruction Algorithm Based on Penalized Weighted Least Squares and Guided Total Variation

Yuwen Zhang, Yujie Liu, Ao Wang, Yikuang Yuluo, Shuangyang Zhong, Haijun Yu, Yixing Huang

Objective. Existing quadratic unconstrained binary optimization (QUBO)-based sparse-view computed tomography (CT) reconstruction neglects photon-counting statistics and anatomical heterogeneity. We address both limitations within the QUBO framework.Approach. We propose a quantum compressed-sensing CT method combining penalized weighted least squares (PWLS) and guided total variation (GTV). PWLS weights projection residuals by photon-count reliability, whereas GTV uses gradients from a prior image reconstructed by the simultaneous algebraic reconstruction technique (SART) to preserve edges and suppress noise in homogeneous regions. After binary encoding, both terms form a unified QUBO model. Experiments used four 40 times 40 CT images under a 10-view fan-beam geometry with Poisson noise. Comparisons included conventional reconstruction methods, QUBO variants, gradient descent, simulated annealing, and a D-Wave hybrid quantum-classical solver.Main results. PWLS-GTV achieved the best reconstruction quality across all cases. In the representative chest case, it reached a peak signal-to-noise ratio (PSNR) of 36.64 dB, compared with 22.48 dB for SART, the best conventional baseline. GTV consistently outperformed conventional total variation. Simulated annealing and the D-Wave hybrid solver produced similar reconstructions, whereas gradient descent was ineffective. Repeated hybrid-solver runs showed stable performance.Significance. The framework incorporates photon-statistical weighting and structure-guided regularization into QUBO-based CT reconstruction without changing its quadratic form, providing a proof of concept for quantum-assisted sparse-view CT reconstruction.

View free PDFSource page

Related papers

arxiveess.IVcs.CVeess.SP2026-07-15

Video to All-in-focus Image Reconstruction Algorithm for Automated Microscopic Urinalysis

Chinmay Nema, Hari Om Aggrawal, Dipam Goswami, Rajiv Gupta, Vinti Agarwal

Microscopic urinalysis is a routine diagnostic test at hospitals. Recent studies have demonstrated the effectiveness of deep learning methods to automate microscopic urinalysis. These methods rely on high-quality images of the urine samples in which each cell is clearly identifia…

View free PDFSource page
arxiveess.IVcs.CV2026-07-03

Motion Estimation Techniques for Volumetric Video Attribute Compression

Haoran Hong, Eduardo Pavez, Antonio Ortega, Ryosuke Watanabe, Keisuke Nonaka

Point cloud compression relies on techniques to compress both geometry and attributes. Motion-based approaches for dynamic solid point cloud geometry compression within the geometry-based point cloud compression (G-PCC) framework have achieved significant reductions in geometry r…

View free PDFSource page
arxiveess.IVcs.CVmath-ph2026-07-14

Efficient Computing for Medical Image Acquisition and Reconstruction

Xiao Wang, Jayasai Rajagopal, Md Safaiat Hossain, Peng Chen, Mohamed Wahib, Enzhi Zhang, et al.

Medical imaging systems such as CT, MRI, PET, and SPECT do not directly acquire images. Instead, they measure physical signals that encode anatomical or physiological information, and image reconstruction recovers the underlying image by solving an inverse problem. Although these…

View free PDFSource page
arxiveess.IVcs.CV2026-07-10

Robustness and Stability Analysis of Differentiable Shift-Variant FBP for Cone-Beam CT under Challenging Acquisition Settings

Chengze Ye, Linda-Sophie Schneider, Yipeng Sun, Mareike Thies, Siyuan Mei, Paula Andrea Pérez-Toro, et al.

The differentiable shift-variant filtered backprojection (SV-FBP) framework enables data-driven estimation of redundancy weights for cone-beam CT reconstruction under general source trajectories, removing the need for analytically derived weighting schemes. In this work, we prese…

View free PDFSource page
arxiveess.IVcs.CVcs.LGmath.NAphysics.comp-ph2026-07-12

Projection-Domain Sensitivity Analysis of Vertebral DRRs Under Intrinsic Calibration Perturbation

Lin Li, Chaochao Zhou, Benjamin Aubert, Junlin Guo, Junchao Zhu

Accurate geometric calibration is essential for fluoroscopy-guided spinal imaging, digitally reconstructed radiograph (DRR) generation, and 2D--3D vertebral registration. Although calibration quality is typically evaluated using reconstruction-based metrics such as reprojection e…

View free PDFSource page