Reliable organ localization in abdominal CT can provide spatial priors for downstream trauma analysis. We propose CT-3GDINO, a lightweight 3D detector that adapts a Grounding-DINO-style query-based architecture to fixed organ localization using frozen pseudo-text class tokens instead of a real text encoder. The model combines a Swin3D visual backbone, bidirectional feature enhancement, pseudo-text-guided query selection, and a cross-modality decoder to predict normalized 3D boxes for liver, spleen, left kidney, right kidney, and bowel. We train and evaluate on 193 matched RSNA/RATIC CT volumes with segmentation-derived boxes. The best multi-scale model, trained from scratch, achieves 0.5830 overall top-1 class-wise mAP over 3D IoU thresholds from 0.1 to 0.7, outperforming fixed- and trainable-backbone classification-pretrained variants with 0.5570 and 0.4657 mAP. Performance is strong for coarse localization, with 0.9649 AP at IoU 0.1, but remains limited for strict box alignment, with 0.1552 AP at IoU 0.7. These results establish CT-3GDINO as an open-source baseline for pseudo-text-conditioned 3D organ localization and motivate future work on localization-aware pretraining, richer multimodal conditioning, and injury-focused detection.
Background: Automated 3D segmentation of muscles and adipose tissue from CT is vital for body composition analysis, but multi-source data heterogeneity and high CPU memory demands hinder clinical deployment. Methods: We propose a coarse-to-fine hierarchical framework to segment t…
Accurate correspondence matching across multiple angiographic views is the prerequisite for 3D coronary reconstruction and interventional guidance. However, the development of robust deep learning models for this task has been stifled by a fundamental data bottleneck. Obtaining g…
Magnetic particle imaging (MPI) enables real-time, radiation-free tracking of magnetic nanoparticle-coated instruments, making it highly suitable for interventional procedures. This study proposes a harmonic-aware transformer framework that directly predicts catheter tip position…
The carbonized papyri from Herculaneum preserve the only large-scale library to survive from classical antiquity, but many unopened rolls remain unread because physical opening risks irreversible damage. X-ray computed microtomography ($μ$CT) and virtual unwrapping offer a non-in…
Learning high-fidelity point-cloud features in the 3D space poses significant challenges, including permutation invariance, lack of local context, difficulty in fine-grained surface reconstruction, and high computational cost. In this article, we propose Trans-Unet, a novel frame…
Mobile C-arm cone-beam computed tomography (CBCT) has been widely used for real-time intraoperative 3D imaging. However, current practice often mechanically applies the fan-beam CT criterion of "180° plus fan angle" in pursuit of "data completeness" in reconstruction. This review…